ZoomTM Stroke System

A system-based approach to aspiration thrombectomy for acute ischemic stroke.

We have developed a standardized system of devices from access through reperfusion that are designed to work together for a seamless, efficient procedure.

The Zoom Stroke System: aspiration catheter, pump, tubing set and PODs

The complete
stroke system

We know that time is brain.

That’s why we engineered the Zoom Stroke System as a complete system — from access through reperfusion — for fast and effective clot removal in a wide range of vessels.

Zoom 71 and Zoom 88 intracranial access catheter inserts
Zoom Aspiration Pump with two PODs

ADAPT 2.0 Technique

Leveraging the combined power of 0.088” Intracranial Access + Asymmetric Aspiration + CDAT for fast, effective clot removal.

0.088” Intracranial Access

Get closer to clot with Zoom 88

Discover more

Zoom 71 and Zoom 88 intracranial access catheters

Asymmetric Aspiration

Zoom 7X with CenTRX Technology

Discover more

Zoom 7X catheter with an asymmetric tip, beside a cross-section diagram of the tip opening
Zoom Aspiration Pump with two PODs

Continuous Dual Aspiration

Enhanced control with Zoom DuoPort

Discover more

1 Data on file2 Vargas et al. JNIS 2020

When every moment matters

Trust the system that provides the fastest time to reperfusion of major prospective mechanical thrombectomy trials.

Discover More

Animated bar chart, five seconds, silent. Title: Groin Puncture to Reperfusion Time (mins). The bars grow to their final lengths and the chart adds no information beyond the values listed here.

Note: individual trials are not directly comparable, and data are presented for observational purposes only.

  • PENUMBRA 3D (SR + Asp arm): 49
  • DAWN: 47
  • ARISE II: 45
  • ASTER (SR arm): 45
  • PENUMBRA 3D (Asp arm): 39
  • ASTER (Asp arm): 38
  • DEFUSE 3: 38
  • COMPASS (SR arm): 33
  • PROST: 27
  • TIGER: 25
  • COMPASS (Asp arm): 22
  • Imperative Zoom System: 19, median groin puncture mTICI2b+

Sources: 1 PENUMBRA 3D, 2 DAWN, 3 ARISE II, 4 ASTER, 5 DEFUSE 3, 6 COMPASS, 7 PROST, 8 TIGER, 9 Zoom System IFU (LBL002069.A); n=211.

Proven, procedure after procedure

Designed for consistency and simplicity; clinically proven for safety and efficacy

Discover More

0.5%

Serious vessel injury*

0.9%

sICH*

* Zoom System IFU (LBL002069.A), n=211

Choose with confidence

Designed for consistency and simplicity; clinically proven for safety and efficacy

Discover More

The Zoom Stroke System device stack

0.035” – 0.088”* for a broad range of asymmetric aspiration

*When used with a Zoom Catheter

Real-world Zoom Stroke System cases

See what the Zoom Stroke System can do.

Request a demo